BMYFW - PROTECTO FLEX

Product Identification

Product ID:PROTECTO FLEX
MSDS Date:09/01/1988
FSC:6850
NIIN:00N028662
MSDS Number: BMYFW

Responsible Party
EASTERN EQUIPMENT & CHEMICAL CO INC
5617 FAIRFIELD RD
COLUMBIA, SC 29203
US

Emergency Phone: 803-754-0542

Info Phone: 803-754-0542

Cage: 0EKY4

Contractor
EASTERN EQUIPMENT & CHEMICAL CO
COLUMBIA, SC 29203 US

Telephone: 803-754-0542

Cage: 0EKY4

Ingredients

MINERAL SPIRITS

CAS: 64742-88-7

Fraction By Weight: 85%


OXYGENATED HYDROCARBON

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NONE.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:INHAL: EXCESSIVE INHALATION CAN CAUSE NASAL &
RESPIRATORY IRRITATION, DIZZINESS, WEAKNESS, FATIGUE, NAUSEA,
HEADACHE & POSSIBLE UNCONSCIOUSNESS. SKIN: PRLONGED CONTACT CAN
CAUSE MODERATE IRRITATION. I NGEST: CAN CAUSE GASTROINTESTINAL
IRRITATION, NAUSEA, VOMITING & DIARRHEA. EYE: CAN CAUSE SEVERE
IRRITATION.
Medical Cond Aggravated by Exposure:PRE-EXISTING EYE, SKIN AND
RESPIRATORY DISORDERS MAY BE AGGRAVATED.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. IF BREATHING DIFFICULT GIVE
OXYGEN. IF BREATHING STOPS GIVE ARTIFICIAL RESPIRATION. GET MEDICAL
ATTENTION. INGEST: DO NOT INDUCE VOMITING. GET MEDICAL ATTENTION.
EYES: FLUS H WITH WATER FOR AT LEAST 15 MIN LIFTING UPPER AND LOWER
LIDS, GET MEDICAL ATTENTION. SKIN: WASH EXPOSED AREA WITH SOAP AND
WATER.

Fire Fighting

Flash Point Method:TOC
Flash Point:133F,56C
Extinguishing Media:FOAM, DRY CHEMICAL, CO2.
Fire Fighting Procedures:KEEP CNTNRS COOL. USE NIOSH/MSHA APPRVD SCBA &
FULL PROT EQUIP. USE EQUIP SHIELDING REQUIRED TO PROT PERSONNEL
AGAINST BURSTING, RUPTURING/VENTING CNTNRS.
Unusual Fire/Explosion Hazard:AT ELEVATED TEMPERATURES (ABOVE 120F)
CONTAINERS MAY VENT, RUPTURE OR BURST.

Accidental Release

Spill Release Procedures:CLEAN UP AREA BY MOPPING OR WITH ABSORBENT
MATERIAL AND PLACE IN CLOSED CONTAINERS FOR DISPOSAL. CONSULT
FEDERAL, STATE OR LOCAL DISPOSAL AUTHORITIES FOR APPROVED DISPOSAL
PROCEDURES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE AT TEMPERATURES ABOVE 120
F.
Other Precautions:PLEASE READ AND FOLLOW THE DIRECTIONS ON THE PRODUCT
LABEL: THEY ARE YOUR BEST GUIDE TO USING THIS PRODUCT IN THE MOST
EFFECTIVE WAY, AND GIVE THE NECESSARY SAFETY PRECAUTIONS TO PROTECT
YOUR HEALTH.

Exposure Controls

Respiratory Protection:NOT APPLICABLE. NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST: GENERAL VENTILATION ADEQUATE.
Protective Gloves:NEOPRENE, NITRILE RUBBER, (SUPP DATA)
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE
Work Hygienic Practices:DO NOT EAT, DRINK OR SMOKE IN WORK AREAS. WASH
HANDS BEFORE EATING.
Supplemental Safety and Health
WASTE DISP METH: FACILITY. CONSULT LOCAL DISPOSAL AUTHORITIES. DISPOSAL
MUST BE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS .
PROT GLOVES: POLYVINYL CHLORIDE.

Chemical Properties

HCC:F4
Vapor Pres:65
Spec Gravity:0.863
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BROWN VISCOUS LIQUID, CHARACTERISTIC ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ACIDS OR BASES, SELECTED AMINES.
Stability Condition to Avoid:DO NOT EXPOSE TO TEMPERATURES ABOVE 120 F.

Disposal

Waste Disposal Methods:WHEN USED PROPERLY AEROSOL PROD DO NOT GENERATE
HAZ WASTE. EMPTY DE-PRESSURIZED CNTNRS CANNOT BE REUSED & SHOULD BE
WRAPPED & PUT IN TRASH COLLECTION. CANS WHICH ARE PRESSURIZED/CNTN
LIQ MUST BE DISP OF IN A PERMITTED WASTE MANAGEMENT (SUPP DATA)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.